![]() And that setting is semi-permanent: power cycling the charger will not reset it. Our Chargers and Solar Chargers automatically configure themselves to be BMS-controlled when they are connected to one either direct or via a GX Device. How to reconfigure the charger to standalone mode Solution: check the connection between the charger and the BMS. And in case there is a permanent problem, the error will raise in the morning and clear at night, and so forth. Solar Chargers only show this error when there is solar power available and thus the device is ready to initiate charging. ![]() This is a safety mechanism, the reason to still enable the output is to allow a system to self-recover from a battery low situation. In that situation, the charger stops charging by reducing its output voltage to the battery base voltage (12V/24V/36V/48V). This error shows when the charger is configured to be controlled by a BMS, but does not receive any BMS control messages.